Ȩ > ¼­ºñ½º > Illumina mRNA chip ½ÇÇè´ëÇ༭ºñ½º
Illumina expression beadchip workflow
1. RNA Quality Check We perform the quality control of total RNA using
Agilent Bioanalyzer 2100 and NanoDrop spectrophotometer
2. Sample Amplification and Labeling Amplification and labeling is performed using
the Ambion illumina RNA amplification kit
3. BeadArray Hybridization Hybridization is performed using illumina expression beadchip kit
4. Wash / Staning Washing is performed using illumina expression beadchip washing buffer kit
5. Scan on BeadArray Reader Arrays were scanned with an illumina bead array Reader confocal scanner
6. Analyze Data Array data export processing and analysis was performed using
illumina Beadstudio (Gene Expression Module)
RNA sample condition
Total RNA Quantity 2ug (70ng/ul)
260/280, 260/230 1.7
28S:18S 2:1
volume 10~15 ul
Detailed instruction illumina expression-»ùÇñâÁØ